How to Crimp SMA Connector: A Practical Workshop Guide

A good SMA crimp takes a few seconds. A bad one can cost hours of troubleshooting because the problem tends to hide until the cable is moved or the frequency goes up. Here is how to terminate crimp-style SMA plugs on RG316, RG174 and RG178, with the dimensions and checks that matter.

Know What You Are Crimping

SMA is a threaded connector with a 50 ohm design that works from DC to about 18 GHz for standard parts. Crimp-style plugs are the common choice for small cables like RG316, RG174 and RG178. They use two crimps: a small one on the center pin and a hex crimp on the ferrule that captures the braid. The most important rule is that the plug and the cable must be matched. An RG316 plug uses a smaller ferrule and pin than an RG58 plug.

Tools You Need

  • An SMA crimp plug listed for your cable.
  • A precision stripper or a hot-knife stripper for PTFE jackets. RG316 has a PTFE dielectric and jacket, and an ordinary blade can nick the inner conductor.
  • A ratcheting crimp tool with the correct hex die. Die sizes vary by plug maker, so use the figure on the plug datasheet.
  • Fine tweezers and a magnifier.
  • A multimeter, plus a VNA if you want proof.

Strip Dimensions

Every plug manufacturer lists its own strip lengths, but the pattern is the same: slide the ferrule on, strip the jacket, fold the braid back, trim the dielectric to expose the center conductor, and leave about 2 to 4 mm of center conductor sticking out past the dielectric depending on the plug. Take the numbers from the datasheet and write them on a card at the bench. A strip that is 1 mm too long leaves a hole in the shield, and one that is 1 mm too short stops the pin seating.

Request a Custom Cable Assembly Contact Our Engineers

The Crimp Sequence

First crimp the center pin. The conductor must show in the inspection hole, and a firm tug should not move it. Next push the dielectric into the plug body until the pin clicks in. The braid should flare evenly over the barrel, with no strands touching the pin. Slide the ferrule over the braid until it meets the body, then crimp. The result should be a symmetrical hex with no cracks or bulges.

Solder or Crimp

MethodStrengthRisk
CrimpRepeatable with the right dieWrong die gives a loose joint
Solder pin, crimp ferruleGood on solid center conductorsOverheating can swell PTFE dielectric
Fully solderedUsed on semi-rigid and some specialty partsWicking and heat damage

Most flexible cable plugs use crimp for the ferrule and either a crimp or solder pin. PTFE cable tolerates heat reasonably well, but melting the dielectric near the pin will move the impedance and raise VSWR.

Testing the Result

Check continuity center to center and shell to shell, and test for no short between the two. Then flex the cable at the connector while watching resistance. For RF, run a VNA sweep over the frequency band you care about. A well-made SMA on RG316 should have low VSWR through several gigahertz. A sudden rise at one frequency usually means a gap or stray braid inside the connector. A slow, steady rise with frequency is normal cable and connector behavior.

Frequent SMA Crimp Errors

  • Using a plain pliers crimp, which leaves a flat or oval joint.
  • Not pushing the dielectric fully into the body, which leaves a gap and a mismatch.
  • Leaving stray braid strands against the pin.
  • Overtightening when mating, which damages the coupling nut. SMA connectors are generally torqued to around 5 in-lb (about 0.56 N-m) with a proper wrench.
  • Mixing standard SMA and reverse polarity RP-SMA parts. They look the same from outside and do not mate.

When to Buy Assemblies Instead

If you need one cable for a prototype, a hand crimp is fine. If you need a dozen with identical electrical length, or if the connector sits at the end of a flexing cable, factory termination with a final test saves time and removes the guesswork about what is actually inside.

Matching Cable and Plug: A Reference

CableTypical plug typeNotes
RG316SMA crimp, PTFE ratedCommon for test and antenna leads
RG174SMA crimp, small ferruleCheaper, higher loss, PVC jacket
RG178SMA crimp, miniatureThin, lightweight, high loss
RG58SMA crimp, larger ferruleLower loss, needs a different plug

The cable must also suit the frequency. RG316 is commonly used through several gigahertz, RG174 and RG178 lose signal quickly as frequency rises, and a perfectly crimped connector cannot rescue a cable that is too lossy for the band.

A Quick Bench Routine

Experienced technicians settle into the same routine every time: check the plug part number, set the strip dimensions, slide the ferrule, strip, inspect, crimp the pin, seat the body, crimp the ferrule, test. Writing the sequence on a bench card reduces mistakes more than any tool upgrade. Keep a few scrap lengths of cable for tool setup, so the first crimp of the day is a practice one.

Worked Example: Ten RG316 Cables With the Wrong Dimensions

A bench worker builds ten cables and the sweeps show a VSWR spike near 5 GHz on four of them. A look at the failed ones shows the center pin crimped a little too deep, and the dielectric bulging at the face. The strip length was a half millimetre too long. After they reset the stripper stops to the connector maker's data, and trim the dielectric flush, the next batch sweeps cleanly. A few tenths of a millimetre make a visible change at several GHz. Keep a gauge or sample part to check the dimension at each shift.

Crimp Tool Check

Use the die size that matches the connector and the cable, and check that the crimp is uniform. A hex crimp should be even all around.

Pull Test

After crimping, pull the cable gently with a gauge or a firm tug, to be sure the center pin and the sleeve hold.

Buy or Build

For repeatable high frequency results, a tested factory built assembly is often a better choice than a hand crimp.

Ordering

We build small lots, sweep each on a VNA for VSWR and insertion loss and ship on a 2-day standard lead time. See [custom coaxial cable assemblies](/custom-coaxial-cable-assemblies/) or [contact us](/contact/).

SigmaRF builds SMA assemblies on RG316, RG174, RG178 and similar cable, each swept on a VNA for VSWR and insertion loss across 100 MHz to 40 GHz. Small lots are welcome, with lead times as short as 2 days.

Request a Custom Cable Assembly Contact Our Engineers