A BNC connector looks simple, which is why so many get installed badly. A poor crimp gives you intermittent dropouts, a VSWR that drifts when someone touches the cable, and a failure that only shows up in the field. This guide covers a correct crimp-style install on RG58, RG59 and RG316, including what to measure before you call the job done.
A BNC plug has three parts that matter electrically: the center contact, the dielectric insulator and the outer body that grips the braid. Your job is to hold the center conductor and the braid firmly while keeping the cable's characteristic impedance intact right up to the mating face. The most common BNC plugs are 50 ohm for RF and test equipment and 75 ohm for video. They look almost identical, so check the label on the plug and the cable before you start. Mixing 50 and 75 ohm parts is allowed mechanically but adds a small impedance step.
Read the jacket print and compare it with the plug datasheet. Measure the cable outer diameter if the print is worn. A plug sized for RG58 will not grip RG316 because the ferrule is far too large, and the center pin will not seat on the thin conductor. Use the plug's published cable list as your authority, not a guess.
Request a Custom Cable Assembly Contact Our Engineers
Slide the ferrule over the cable first. This is the step people forget, and it means cutting the connector off and starting again. Then strip the jacket, comb the braid back over the jacket, trim the dielectric, and leave the center conductor at the length the datasheet gives. Do not nick the conductor. A nicked strand work-hardens, then snaps after a few weeks of flexing. Keep the dielectric cut square, because an angled cut leaves a gap behind the pin.
Seat the pin so the conductor is visible in the inspection hole, then crimp it with the small die. Give the pin a light pull. If it moves, cut it off and redo it. Soldering the pin is also acceptable on solid center conductors, but use as little solder as possible and let it cool fully, because excess solder wicks into the pin and swells it past the size the insulator expects.
Push the body over the dielectric until the pin clicks into place. The braid should lie evenly over the body's barrel with no strands near the center contact. Slide the ferrule forward until it touches the shoulder, then crimp it with the hex die. A good ferrule crimp is evenly hex shaped, not oval, and does not crack the ferrule. This crimp is also your strain relief, so it matters mechanically as much as electrically.
First do continuity from center to center and shell to shell, and check for no short between pin and shell. Then flex the cable near the connector while watching the reading. If the resistance jumps, the crimp or the pin is bad. For RF work, a VNA sweep is the real test. A good BNC on matched cable should show return loss that stays well within the connector's frequency range and insertion loss that tracks the cable's own loss.
| Mistake | What it causes | Fix |
|---|---|---|
| Ferrule left off before stripping | Wasted connector, reterminate | Slide it on first, every time |
| Nicked center conductor | Intermittent open after flexing | Use a stripper set, not a blade |
| Stray braid touching the pin | Short or noisy signal | Comb and trim, inspect under magnification |
| Pliers instead of a ratchet tool | Oval, loose crimp | Use the correct die and a ratchet |
| 75 ohm plug on 50 ohm cable | Extra reflections at higher frequency | Match impedance end to end |
Standard 50 ohm BNC connectors are specified to about 4 GHz, and the bayonet coupling is quick to use but less repeatable than a threaded connector at the top of that range. Many designs treat 2 to 3 GHz as the comfortable ceiling for routine work. Above that, the slot geometry and contact gap start to show up as rising VSWR. If your signal sits in the gigahertz range and the cable will be moved around, a threaded SMA or TNC is usually the safer choice. For video, audio, bench instruments and general lab work below a few hundred megahertz, BNC remains an excellent, fast to use option.
Hand crimping is reasonable for a bench repair or one cable. It stops making sense when you need several identical cables, when length or phase consistency matters, or when someone needs a test report with the delivery. A factory process uses calibrated crimp tooling, controlled strip lengths and a test at the end, and the result repeats from cable to cable.
A BNC cable carries a 75 ohm video signal, and a flicker appears at one end. The connector has a loose center pin, so the signal drops out when the cable moves. The installer cuts off the plug, checks the strip dimension against the connector datasheet, and recrimps with the right die. After the new termination, a gentle pull test shows no movement, and the flicker is gone. The root cause was a crimp tool set for a different cable size. Always match the tool die to the connector and cable.
Many BNC plugs for video are 75 ohm, and for RF they are 50 ohm. They look alike, so mark each cable and keep them separate.
Check continuity from center to center and braid to shell, and check that there is no short between the center and the shell.
We build small lots, sweep each on a VNA for VSWR and insertion loss and ship on a 2-day standard lead time. See [custom coaxial cable assemblies](/custom-coaxial-cable-assemblies/) or [contact us](/contact/).
SigmaRF builds custom BNC cable assemblies on RG58, RG59, RG316, RG174 and similar cable, in small lots with no large minimum. Each assembly is swept on a VNA for VSWR and insertion loss, with lead times as short as 2 days from our Vadodara and Cleveland facilities.