N-type connectors are the workhorse of outdoor and base-station RF, and LMR-400 style cable is the usual partner. The pairing carries power and signal well, but only if the connector is fitted correctly and sealed against weather. This is the install sequence, with the checks that catch problems before the cable goes up a mast.
LMR-400 is a 0.405 inch outer diameter, 50 ohm cable with a solid bare copper-clad aluminum center conductor, a foam polyethylene dielectric, an aluminum foil wrap and a tinned copper braid. Published loss is roughly 3.9 dB per 100 feet at 900 MHz and 6.6 dB per 100 feet at 2.4 GHz, which is why it replaces RG58 on runs longer than a few meters. N-type is a threaded, constant-impedance connector that handles these frequencies comfortably and can be weatherproofed with a rubber O-ring seal and tape or boot.
Slide the boot, heat shrink or crimp sleeve on first if your connector uses one. Cut the cable end square. Remove the jacket to the length shown on the datasheet, usually around 15 to 20 mm, and be careful not to cut the braid. Fold the braid back and trim the foil and dielectric so the center conductor is the exact exposed length. A common mistake is leaving too much dielectric on or cutting too far back, and either one changes the impedance right at the connector.
Fit the center pin. On solder pins, tin the conductor lightly and solder briefly, then confirm the pin sits flat against the dielectric. On crimp pins, crimp once with the correct cavity and tug the pin. Push the body onto the cable so the braid and foil sit under the clamp or crimp sleeve. Tighten the clamp nut or crimp the sleeve with a hex die. The finished crimp must be evenly hex shaped and tight enough that the cable cannot rotate by hand.
Request a Custom Cable Assembly Contact Our Engineers
Moisture is the leading cause of N-type connector failure outdoors. Water enters at the cable jacket and wicks along the braid into the connector, raising loss and eventually corroding the pin. Use a connector with a jacket seal or put adhesive-lined heat shrink over the rear of the body. Over the mated pair, use self-amalgamating tape, then a layer of vinyl tape, then a second layer of self-amalgamating tape. Make a drip loop in the cable below the connector so water runs off rather than down into it.
| Check | Pass condition | Tool |
|---|---|---|
| Pin-to-pin continuity | Low, steady resistance | Multimeter |
| Shell to pin | No short | Multimeter |
| Return loss at your band | Stable, within system limit | VNA or antenna analyzer |
| Mechanical pull | Cable does not move in the clamp | Hand test |
| Seal | Tape or boot covers the full joint | Visual |
A VSWR that is acceptable on the bench but worsens in the rain points to water ingress. A reading that changes when you flex the cable points to a loose crimp or a nicked center conductor. A high reading at all frequencies points to a short, a wrong plug for the cable, or a pin pushed too far. If the VSWR is only high at the upper end of the band, the strip dimensions are probably off and the transition is poorly matched.
N-type is hand tightened in most installations, and over-tightening with pliers damages the coupling nut. Use a wrench only where the application calls for a specified torque, and never twist the cable while tightening, because it can loosen the pin inside the connector.
Field-terminated connectors suit one-off installs. For anything that must be repeated, consistent in length, or delivered with test data, a factory assembly is more predictable. A lab crimp, a controlled strip and a final sweep take the variation out of the job.
Three N-type plug styles are common on 400-series cable. Clamp-style plugs use a threaded nut and need only a wrench, which makes them forgiving for field work. Crimp plugs give a more consistent, lower-profile result but need the correct die. Solder-pin plugs with a clamped braid are the traditional choice for low-loss installs. None of them is automatically better, but the mixed styles have different failure patterns. Clamp types loosen under vibration, crimp types fail when the die is wrong, and solder types fail when heat distorts the dielectric. Pick the one your team can make repeatably with the tools available.
The connector is only one part of an outdoor run. Calculate the total loss using the cable length, add about 0.1 to 0.2 dB for each connector pair as an allowance, and compare it with the system margin. Add a lightning arrestor if the run goes to a mast, and label both ends. A well planned install leaves slack for re-termination, because the first inch of cable gets cut away whenever a connector is replaced.
A 25 m run of LMR-400 type cable runs from a rooftop antenna to a cabinet. The installer builds two N male clamp connectors with the tool kit, strips the jacket to the length in the connector datasheet, folds back the braid, fits the pin, solders or crimps it as the part requires and screws the body on. Each joint is wrapped with sealing tape. LMR-400 loses roughly 0.13 dB per metre at 900 MHz, so the run costs about 3.3 dB, which is acceptable. After the build, the installer checks the continuity and return loss of the run with a cable analyzer, and a poor reading points to one of the two connectors.
Use a sharp cutter, and trim any loose braid strands or foil that could short the pin to the shell.
Inspect the tape and boots after the first storm, and fix any cracks right away.
We build small lots of assemblies, sweep each on a VNA for VSWR and insertion loss and ship on a 2-day standard lead time. See [custom coaxial cable assemblies](/custom-coaxial-cable-assemblies/) or [contact us](/contact/).
SigmaRF builds custom N-type cable assemblies on 400-series, RG213, RG58 and other cable, with every assembly swept on a VNA for VSWR and insertion loss from 100 MHz to 40 GHz. Small lots are welcome and lead times can be as short as 2 days from Vadodara and Cleveland.