Coax Cable Temperature Ratings: Operating Ranges by Jacket Material

Published on 10/13/2026

A cable assembly is specified for an under-hood sensor at 125 C. The datasheet lists the dielectric as PTFE, which is fine, and the jacket as PVC, which is not. The signal still works on day one, then the jacket softens, cracks and exposes the braid. Temperature ratings belong to every layer, and the lowest one wins.

Short answer: PVC jackets are rated about -40 to +80 C, polyethylene about -55 to +85 C, and FEP and PTFE about -65 to +200 C. Silicone jackets reach about +180 C. Cable operating range is set by the weakest layer: jacket, dielectric, braid plating or connector.

The table below lists typical limits by jacket and dielectric. Check the datasheet of the exact cable.

On This Page

Operating Range by Jacket Material

Jacket materialTypical range (C)Notes
PVC-40 to +80 (some to +105)Low cost; stiffens in cold
Polyethylene (PE)-55 to +85Good UV resistance, outdoor use
Polyurethane (PU)-40 to +90Abrasion and oil resistance
LSZH (low smoke zero halogen)-40 to +70 (some to +105)Fire-safety use; check grade
Cross-linked polyolefin-55 to +125Heat and chemicals
Silicone-60 to +180Very flexible; low abrasion strength
FEP-65 to +200RG316, RG400, RG142 class
PTFE-65 to +200 (up to 250 for some)Highest range; costly

Ranges are typical and vary by compound. Always read the datasheet.

Dielectric and Other Limits

LayerTypical limitEffect beyond limit
Solid PE dielectricAbout 85 CSoftens, center conductor migrates
Foam PE dielectricAbout 80 to 85 CCollapses, impedance shifts
PTFE dielectricAbout 200 C or higherVery stable
Silver-plated copper braidUp to 200 CStable
Tin-plated braidUp to about 150 COxidizes at high temperature
Standard connectors (PTFE, gold)About 165 CCheck connector spec
Solder joints (tin-lead or lead-free)About 150 C workingWeakens near reflow range

Key idea: The usable range of an assembly is the lowest rating among cable, connector, solder and cable-to-connector bond. Check each.

High-Temperature Assemblies

PTFE and FEP assemblies built to order

Tell us the temperature range and frequency. We will build the assembly and sweep it on a VNA for VSWR and insertion loss before shipment.

Talk to an Engineer

Low-Temperature Behavior

Cold makes PVC stiff and brittle. A cable rated to -40 C should not be flexed at that temperature. FEP and PTFE keep their flexibility to about -65 C. Silicone stays flexible below -60 C. Handle and install cable at room temperature when possible.

EnvironmentRecommended
Outdoor, -40 to +70 CPE jacket cables (RG213, LMR with PE)
Under hood or industrial, to +125 CFEP or cross-linked jacket
Aerospace, to +200 CPTFE or FEP with silver-plated braid
CryogenicSpecialty PTFE or semi-rigid; check shrinkage

Temperature and RF Performance

Loss rises slightly with temperature because conductor resistance increases. For copper, resistance rises about 0.4 percent per degree C, so loss rises about 0.2 percent per degree C because loss follows the square root of resistance. From 25 C to 125 C that is about 20 percent more loss. PTFE cables also show a small phase change near 19 C where the dielectric changes crystal structure, which matters for phase-matched cables.

Mistakes

Avoid

  • ✗Specifying PTFE dielectric but ignoring the PVC jacket rating.
  • ✗Using solder rated below the working temperature.
  • ✗Forgetting that radiation heating or hot surfaces raise cable temperature above ambient.
  • ✗Flexing cold PVC cable.
  • ✗Using tin-plated braid in sustained high heat.

Cable Temperature FAQ

What is the temperature rating of RG58?

Typically -40 to +80 C with a PVC jacket, or up to +85 C for PE jacket versions.

What is the temperature range of RG316?

About -55 to +200 C, because of the PTFE dielectric and FEP jacket.

What is the maximum temperature for PTFE cable?

About 200 C for most cable, and up to 250 C for special versions.

Does temperature change coax loss?

Yes. Loss rises about 0.2 percent per degree C for copper conductors.

Which coax cable is best for high temperature?

PTFE or FEP cables such as RG316, RG400 and RG142, or semi-rigid cable.

What jacket is best for cold weather?

FEP, PTFE, silicone or PE. PVC gets stiff below about -20 C.

Bottom Line

Read the temperature rating of every layer, not just the jacket or dielectric. Use PE for outdoor, FEP or PTFE for heat, and check connectors and solder for the full assembly.