Coaxial Cable Attenuation Chart: RG58, RG316, RG174, RG213, LMR (dB/m at 8 Frequencies)

Published on 10/13/2026

You are choosing between RG316, RG58 and LMR-240 for a 2.4 GHz run and want the loss numbers on one page, not scattered across seven datasheets. This chart gives approximate attenuation in dB per meter for the common RG and LMR cables at eight frequencies from 100 MHz to 10 GHz.

Short answer: loss rises with the square root of frequency and falls as the cable gets larger. At 2.4 GHz, RG174 loses about 1.7 dB/m, RG316 about 1.4, RG58 about 1.2, LMR-240 about 0.6 and LMR-400 about 0.35.

Values are typical planning figures. Individual makers differ by 10 to 20 percent, so confirm against the datasheet of the exact cable before you finalize a link budget.

On This Page

Attenuation Chart: dB per Meter

Cable100 MHz400 MHz1 GHz2.4 GHz3 GHz5.8 GHz8 GHz10 GHz
RG1740.300.601.051.71.92.73.13.4
RG3160.300.550.901.41.62.22.63.0
RG580.160.370.721.21.31.92.22.5
RG2130.100.230.450.740.821.151.351.5
LMR-195 class0.170.340.550.80.91.31.51.7
LMR-240 class0.120.240.380.600.670.951.11.25
LMR-400 class0.070.140.220.360.400.580.680.76

Amber values are above the frequency where the cable is normally rated or the connectors are practical. They are shown for comparison, not as a recommendation. To convert dB per meter to dB per 100 ft, multiply by 30.48.

How to Read the Chart

Step 01

Pick the frequency column

Use the highest frequency in your band, not the center.

Step 02

Multiply by length

Loss in dB is the dB per meter value times the length in meters.

Step 03

Add connectors

Add 0.1 to 0.2 dB per connector pair for SMA, N and BNC at these frequencies.

Step 04

Add margin

Add 10 percent for aging, bends and manufacturing spread.

Example: 3 m of RG316 at 2.4 GHz with two SMA connectors
Cable = 3 x 1.4 = 4.2 dB
Connectors = 2 x 0.1 = 0.2 dB
Subtotal = 4.4 dB, with 10 percent margin = 4.8 dB

Need Lower Loss Than the Chart?

Get the right cable for your frequency

Send frequency, length and connectors. We will recommend and build the assembly, with every unit swept on a VNA for VSWR and insertion loss.

Talk to an Engineer

Interpolating Between Frequencies

Between table points, scale by the square root of the frequency ratio. If a cable loses 1.4 dB/m at 2.4 GHz, expect about 1.4 x sqrt(5.0 / 2.4) = 2.0 dB/m at 5.0 GHz. This is accurate to about 10 percent for solid-dielectric cables, and slightly low at high frequency where dielectric loss grows.

Key idea: Doubling the cable diameter roughly halves the loss. That is why LMR-400 has about a third of the loss of RG58, at the cost of a stiffer 10.3 mm cable.

Which Cable for Which Job

NeedGood choiceWhy
Short internal jumper, flexibleRG316 or RG178Small, PTFE, handles heat
General lab and antenna runs to 1 mRG316 or RG58Common, easy connectors
Runs of 3 to 10 m at UHF or 2.4 GHzLMR-240 classGood loss for 6 mm size
Long outdoor runsLMR-400 class or RG213Lowest loss, outdoor rated
18 GHz and aboveSemi-rigid or microwave flexNot RG58 or RG316

For the single-case loss calculation, see the loss calculator guide in this series. For RG316 at high frequency, see the RG316 maximum frequency article.

Chart Mistakes

Avoid

  • ✗Using a datasheet value for a different frequency.
  • ✗Forgetting that loss is per meter, not per foot.
  • ✗Comparing cables at different frequencies.
  • ✗Ignoring connector and adapter loss.
  • ✗Using the chart for cables with different dielectric (foam or air-spaced) without checking.

Attenuation Chart FAQ

What is the attenuation of RG58 at 2.4 GHz?

About 1.2 dB per meter, so 5 m costs about 6 dB.

Which coax has the lowest loss?

Larger cable has lower loss. LMR-400 class loses about 0.36 dB/m at 2.4 GHz, compared to 1.4 dB/m for RG316.

How much does RG316 lose at 5.8 GHz?

About 2.2 dB per meter.

How do I convert dB per 100 ft to dB per meter?

Divide by 30.48.

Does loss depend on cable length linearly?

Yes. Loss in dB is proportional to length.

Are these values exact?

No. They are typical planning values; makers differ by 10 to 20 percent.

Bottom Line

Use the chart to compare cables at the same frequency, multiply by length, and add connectors and margin. If the number is more than your budget allows, step up the cable size or shorten the run.

SigmaRF builds assemblies on RG174, RG316, RG58, RG213 and low-loss cable in India (Vadodara) and the USA (Cleveland area), VNA-swept before shipment, with lead times as short as 2 days.

Build the cable you picked

Standard or custom, swept before shipment.

Standard AssembliesCustom AssembliesTalk to an Engineer