LMR-400 vs LMR-240 vs LMR-195: Low-Loss Cable Selection Guide

Published on 10/13/2026

LMR-400 generally gives the lowest attenuation of these three standard 50 Ω cable sizes, while LMR-240 and LMR-195 reduce diameter and routing burden. Choose the smallest cable that still meets the actual feeder loss, environmental and connector requirements. A larger cable is not automatically the better assembly.

A 10 m antenna run can justify a larger cable where a 300 mm jumper cannot. At 900 MHz, published typical cable-only loss over 10 m is about 1.28 dB for LMR-400, 2.48 dB for LMR-240 and 3.65 dB for LMR-195. That difference should be compared with the installation effort, not judged by cable names alone.

The figures below refer to the named standard constructions in their published datasheets. Ultra-flex, fire-rated, direct-burial and other variants need their own specifications. SigmaRF can build a cable system to the agreed drawing, but confirm the exact approved cable and connector parts rather than treating similar-diameter products as interchangeable.

On This Page

LMR-400 vs LMR-240 vs LMR-195 at a glance

PropertyLMR-400LMR-240LMR-195
Nominal impedance50 Ω50 Ω50 Ω
Nominal diameter10.29 mm6.10 mm4.95 mm
Velocity factor84%83%80%
Nominal delay3.92 ns/m3.97 ns/m4.17 ns/m
Inner conductorSolid copper-clad aluminumSolid bare copperSolid bare copper
Shield constructionAluminum tape plus tinned-copper braidAluminum tape plus tinned-copper braidAluminum tape plus tinned-copper braid
DielectricFoam PEFoam PEFoam PE

Foam dielectric reduces capacitance and raises propagation velocity compared with many solid-PE miniature cables. That does not create a universal phase-stability rating. Shielding effectiveness, loss and handling remain product and assembly properties; braid coverage alone is not a dB screening test.

Key idea: The comparison is between exact named cable constructions. A cable described as "400 size" or "equivalent" needs its own loss, materials, jacket and connector approval data.

Compare cable loss at the same frequency

Compare typical attenuation in dB per the same length at the same frequency. The table uses published dB/100 m figures divided by 100. The listed cable-loss conditions are matched VSWR 1.0 and +25 °C ambient, not a maximum guarantee for a connectorized feeder.

FrequencyLMR-400 dB/mLMR-240 dB/mLMR-195 dB/m
150 MHz0.0500.0990.146
450 MHz0.0890.1730.255
900 MHz0.1280.2480.365
1500 MHz0.1680.3240.477
2500 MHz0.2220.4240.624
5800 MHz0.3550.6680.981
8000 MHz0.4270.7971.171

At 2.5 GHz, 10 m contributes about 2.22 dB for LMR-400, 4.24 dB for LMR-240 and 6.24 dB for LMR-195. At 5.8 GHz, the same lengths contribute about 3.55, 6.68 and 9.81 dB. Connectors, mismatch, temperature and installation damage can add to the finished-system result.

Use the point matching your radio band, or a manufacturer-supported calculation for that band. The 2.5 GHz row should not silently become a 2.4 GHz guaranteed value. Table endpoints also do not prove that any selected connectorized assembly is qualified to 8 GHz.

Diameter, bend radius and connector fit

Diameter affects enclosure fit, bend space, clamp size and the force applied to a panel connector. Standard LMR-400 is approximately twice the diameter of LMR-195. A large cable hanging off a small device can defeat an otherwise good RF design through mechanical strain.

Routing checkPublished standard examplesDecision
LMR-400 installation / repeated bend25.4 mm / 101.6 mm radiusDo not apply installation radius to repeated movement
Cable groupsDifferent ferrules, contacts and preparation per sizeChoose the exact connector variant
Jacket versionsOutdoor, general-purpose and fire-rated variants differSpecify environmental and fire requirements
Power tablesDepend on VSWR, temperature, altitude and conditionsObtain an assembly power/derating basis

A repeated-bend radius is not a guarantee of unlimited flexing. If a mast, test setup or equipment door moves repeatedly, define the motion and choose the appropriate construction. Stranded ultra-flex versions can differ electrically and mechanically from the standard solid-conductor versions used in this comparison.

⚠️ Peak power, average CW power, dielectric withstand and jacket spark-test voltage are different limits. Never turn one into another or apply cable-only power directly to a connectorized assembly.

Which low-loss coax should you choose?

Choose LMR-400 when cable loss dominates and its size and routing fit. Choose LMR-240 for a smaller route when its additional loss is acceptable. Choose LMR-195 for short compact links where the loss budget allows it, not as a default long high-frequency feeder.

Antenna feedersWireless equipmentRF jumpersOutdoor links with suitable jacket

Lowest loss priority

For a long route, evaluate LMR-400 first, then check strain relief, connector compatibility and installation geometry.

Compact routing priority

For a short jumper or crowded equipment route, evaluate LMR-240 or LMR-195 and calculate the actual loss penalty.

For a 0.3 m 900 MHz jumper, the cable-only difference between LMR-400 and LMR-195 is about 0.071 dB. That may not justify the larger cable burden. Over 10 m it is 2.37 dB. This is why the best answer changes with length. SigmaRF's cable selection and RF attenuation guides cover the wider cable-family decision.

Specify the complete RF assembly

Send the frequency band, connector interfaces, finished length and routing drawing. SigmaRF can match the cable and terminations to your application.

Specify the finished assembly

Step 01

Select the exact cable construction

State the brand/part where required or define the approved alternative and evidence. Specify the jacket version, environment and any fire or burial requirements. Do not assume performance from diameter alone.

Step 02

Select compatible terminations

Define connector family, interface, polarity, angle and cable group. Use the exact stripping and termination instructions. Support heavier cable near the equipment instead of loading a small panel interface.

Step 03

Define assembly acceptance

Give finished length, tolerance and measurement datums, plus VSWR and insertion-loss limits across the operating band. Agree reference planes and fixture handling before comparing reports.

SigmaRF VNA-sweeps every assembly for VSWR and insertion loss before shipment. Its overall RF assembly capability spans 100 MHz to 40 GHz across suitable cable and connector systems, not every product discussed here. Volume work is supported in Vadodara, India, with precision work in the Cleveland area, USA. Lead times can be as short as 2 days for suitable builds, subject to parts, quantity and the agreed specification.

SigmaRF's company-wide 40 GHz capability does not rate these cable assemblies to 40 GHz. The approved cable, connectors and sweep band set the ordered product's limits. Use the RF assembly design and VNA measurement guides for installation reliability and test interpretation.

Worked example: a 10 m antenna feeder

Assume a 10 m feeder at 900 MHz, with a hypothetical total 0.20 dB connector allowance. Use the published typical cable values; the following is a comparison estimate, not an assembly guarantee. Suppose the target budget is 2.00 dB.

LMR-400: 0.128 x 10 + 0.20 = 1.48 dB

LMR-240: 0.248 x 10 + 0.20 = 2.68 dB

LMR-195: 0.365 x 10 + 0.20 = 3.85 dB

LMR-400 nominal budget margin = 2.00 - 1.48 = 0.52 dB

Matched power ratio for 1.48 dB = 10^(-1.48/10) = 0.711, about 71.1%

Only the largest of these standard examples fits the hypothetical nominal budget. It still needs verification and variation allowance. If it cannot be routed safely, shorten the run, move the radio or investigate another suitable low-loss cable rather than forcing a tight bend into the installation.

Selection mistakes to avoid

Avoid misleading comparisons

  • ✗Comparing dB/100 ft with dB/100 m without conversion.
  • ✗Using an ultra-flex datasheet for a standard solid-conductor cable or the reverse.
  • ✗Calling every similarly sized cable identical to the named LMR construction.
  • ✗Applying a cable loss endpoint as a complete assembly frequency rating.
  • ✗Ignoring environmental jacket versions or connector weather sealing.
  • ✗Selecting the lowest loss cable without checking connector strain and routing.

Procurement checklist

  • ✓Approved cable and jacket variant.
  • ✓Frequency, finished length and loss budget.
  • ✓Compatible connector parts and strain relief.
  • ✓Bend geometry and environment.
  • ✓Assembly test band, limits and required reports.

Low-loss cable questions

Is LMR-400 better than LMR-240?

Its standard construction has lower typical attenuation, but is larger at about 10.29 mm versus 6.10 mm. The better choice depends on length, loss budget, routing and connector strain.

What is the difference between LMR-240 and LMR-195?

The standard diameters are about 6.10 mm and 4.95 mm. At 900 MHz their typical cable losses are 0.248 and 0.365 dB/m, respectively. Check exact variants before selecting.

Which cable should I use for a 10 m antenna feeder?

Calculate at the actual band. In the 900 MHz example here, cable-only typical loss is 1.28 dB for LMR-400, 2.48 dB for LMR-240 and 3.65 dB for LMR-195. Add connector and design margin.

Does LMR-400 mean outdoor or direct-burial cable?

The jacket variant matters. Standard outdoor, watertight/direct-burial and fire-rated versions have different designations and approvals. Specify the exact cable and interface sealing.

Can I use the same connectors for all three sizes?

Not by cable-family name. Each size needs an approved connector cable group, ferrule/contact fit and preparation instructions.

Can SigmaRF build a low-loss custom assembly?

Provide the exact approved cable, connector interfaces, length, environment and RF acceptance limits. SigmaRF can agree the build and verification method; confirm part availability and lead time.

Bottom Line

LMR-400, LMR-240 and LMR-195 solve different compromises between attenuation and routing. The loss advantage of larger cable grows with frequency and length. In a short jumper, mechanical fit can dominate.

Select the exact variant, compute at the operating band and verify the finished assembly. A clear drawing and test limit are more useful than a blanket recommendation that one size is always best.

Build an RF assembly around the real requirements

Send the frequency band, connector interfaces, finished length and routing drawing. SigmaRF can match the cable and terminations to your application.