What Is the Power Handling of RG58, RG316 and LMR-400?

Published on 10/13/2026

A designer connects a 20 W transmitter to a 10 cm RG316 jumper at 2.4 GHz and the PTFE jacket smells hot after an hour. Meanwhile a ham pushes 100 W through RG58 at 14 MHz for years without a problem. Cable power handling is not a single number. It depends on frequency, temperature and mismatch.

Short answer: RG58 handles roughly 200 W at 100 MHz and about 55 W at 1 GHz, RG316 about half of those, and LMR-400 class cable several hundred watts at 1 GHz. All values are typical average-power ratings at 25 C and a matched load, and they fall quickly as frequency and temperature rise.

This guide explains why, shows typical figures and gives a quick method to derate for your own conditions.

On This Page

Typical Average Power Ratings

Average power is limited by heating. The cable loses power as heat along its length, and the dielectric and jacket have a maximum temperature. Figures below are approximate, from typical manufacturer data at 25 C ambient, matched load, still air. Check the exact datasheet for your cable.

Cable100 MHz400 MHz1 GHz2.4 GHz
RG58 (PE dielectric)200 W90 W55 W30 W
RG316 (PTFE)150 W70 W40 W25 W
RG213 (PE)700 W330 W200 W110 W
LMR-400 class1,300 W700 W400 W250 W

Key idea: Power rating falls roughly with the square root of frequency, because loss rises that way and heat is what sets the limit.

What Sets the Limit

Limit 01

Conductor and dielectric heating

Loss turns RF into heat. Small cable has little surface to shed it.

Limit 02

Dielectric temperature

PE softens near 80 C. PTFE tolerates 200 C, which is why RG316 beats RG58 in hot spots despite its size.

Limit 03

Peak voltage breakdown

Pulsed or high-VSWR signals can arc. Peak power limit is much higher than average, but it depends on pulse width.

Limit 04

Connector limits

SMA and BNC connectors limit before the cable at high power. N type handles far more.

Power Level Beyond These Numbers?

Let us size the assembly

Send frequency, average power, VSWR and ambient temperature. We will recommend cable and connectors, and sweep the finished assembly on a VNA.

Talk to an Engineer

How to Derate for Real Conditions

ConditionDerating guide
Ambient 50 C instead of 25 CCut rating by about 30 to 40 percent (PE cable)
VSWR 2:1 on the lineCut rating by about 20 to 30 percent
Cable bundled with others or in conduitCut by another 20 to 40 percent
Altitude above 3,000 mCut peak power; heat shedding is worse
Sunlight and outdoor heatCut by 20 percent or more
Example: RG58 at 1 GHz: 55 W rated at 25 C
Ambient 45 C: x 0.7 = 38 W
VSWR 2:1: x 0.75 = 29 W
Real safe power = about 29 W
Rule: stay at 50 percent of the derated figure for margin = about 15 W

Choosing a Cable by Power

As a quick guide: for under 10 W up to 6 GHz, RG316 is fine. For up to 50 W at VHF and UHF, RG58 or RG400 work. Above 100 W, use RG213, LMR-400 class or larger cable, and N or 7/16 DIN connectors. Our cable selection guide has the full tree.

Mistakes With Power Handling

Avoid

  • ✗Using the HF rating at UHF or microwave.
  • ✗Ignoring VSWR, which concentrates heat at current maxima.
  • ✗Using SMA or BNC at high power without checking the connector rating.
  • ✗Running thin cable inside a hot enclosure.
  • ✗Mixing average and peak power ratings.

Power Handling FAQ

What is the power handling of RG58?

About 200 W at 100 MHz, 90 W at 400 MHz and 55 W at 1 GHz, at 25 C and matched load.

How much power can RG316 handle?

Roughly 150 W at 100 MHz, 70 W at 400 MHz and 40 W at 1 GHz. PTFE gives it better temperature tolerance than RG58.

What is the power rating of LMR-400?

Typical average power ratings are about 1.3 kW at 100 MHz and around 400 W at 1 GHz.

Does VSWR reduce power handling?

Yes. High VSWR creates hot spots in the cable and cuts safe power by 20 to 30 percent at 2:1.

Why does power rating drop with frequency?

Loss rises with frequency, so more power turns into heat in the same length of cable.

Is average or peak power more important?

Average power for heating and peak power for breakdown. Check both for pulsed systems.

Bottom Line

Treat cable power ratings as frequency-dependent and derate for heat and mismatch. When in doubt, pick one cable size up.

SigmaRF builds RG58, RG316, RG213 and low-loss assemblies in India (Vadodara) and the USA (Cleveland area), swept on a VNA before shipment, with lead times as short as 2 days.

Need an assembly for higher power?

Send the frequency and power level.

Standard AssembliesCustom AssembliesTalk to an Engineer