RG58 vs LMR-240: Same Size, Very Different Loss

Published on 10/13/2026

A gateway sits 10 m from its antenna. The old RG58 feeder fits the conduit, so a replacement cable that looks only slightly thicker seems like a simple upgrade. The signal-loss benefit can be real, but connector fit and routing still need engineering attention.

LMR-240 usually has lower attenuation than conventional RG58, but they are not the same size. A representative RG58 is 4.90 mm in overall diameter; standard LMR-240 is 6.10 mm. That difference changes connector preparation, ferrule choice, bend space and entry seals.

The title's "same size" is best understood as a compact-cable comparison, not dimensional interchangeability. Use exact cable part numbers and current datasheets. RG58 is a family designation, so construction and attenuation vary between products.

On This Page

Dimensions and construction are different

The representative RG58 data below describes a solid-conductor, PE-insulated RG58/U product, not every RG58 cable. The LMR-240 values describe the standard solid-conductor cable, not an ultraflexible or fire-rated variant. Do not transfer these numbers to a similarly named cable without checking its datasheet.

PropertyRepresentative RG58/UStandard LMR-240
Overall diameter4.90 mm6.10 mm
DielectricSolid PEFoam PE
ShieldSingle copper braid in the reference productAluminum tape plus tinned copper braid
Nominal velocity factor66% in the reference product83% in the reference datasheet
Impedance detailReference RG58/U datasheet states 52 ohm50 ohm
TerminationCable-specific strip lengths and ferruleDifferent cable-specific strip lengths and ferrule

Key idea: A nominal 50 ohm application does not guarantee that every product labelled RG58 has exactly 50 ohm nominal impedance. The reference RG58/U data states 52 ohm; qualify the selected cable.

Compare attenuation at the same frequency and length

At 900 MHz, the reference RG58/U product lists 13.7 dB per 100 ft. The standard LMR-240 datasheet lists 24.8 dB per 100 m. Convert the units before comparing. A 100 ft length is 30.48 m, not 100 m.

The converted RG58 loss is approximately 0.449 dB/m; LMR-240 is approximately 0.248 dB/m at the same frequency. These are nominal or typical bulk-cable values under the respective datasheet conditions. An assembly includes connector losses and production variation. Use tested acceptance limits for an actual purchase.

Do not extrapolate a single-frequency comparison to all bands with a fixed loss ratio. Conductor and dielectric losses vary with frequency. Also avoid assigning a generic 2.4 GHz RG58 value when the selected product's published table stops at 1 GHz. Obtain supporting data or measure the assembly.

900 MHz estimateReference RG58/UStandard LMR-240
Bulk cable loss per meter0.449 dB/m0.248 dB/m
Bulk cable loss over 10 m4.49 dB2.48 dB
Matched power remaining over 10 mApproximately 35.6%Approximately 56.5%

Get the interface right before ordering

Send the equipment-port details, cable length and operating band to SigmaRF.

Specify a Custom Assembly

Why lower loss can cost routing space

The lower-loss cable uses a different geometry and construction. A larger center conductor, foam dielectric and combination shielding change the electrical and mechanical trade-offs. Do not simplify the improvement to "double shielding means half the attenuation." Shielding effectiveness and insertion loss are separate parameters.

Standard LMR-240 has a solid center conductor. A cable intended for repeated motion needs its own dynamic-flex qualification; a minimum installation bend radius does not establish a fatigue life. Compare the standard and flexible variants by their actual mechanical data.

A connector intended for RG58 is not automatically suitable for LMR-240. Cable diameter alone is insufficient: center-conductor diameter, dielectric diameter, shield termination and ferrule all matter. A connector may share the same mating interface while needing a completely different cable-end termination.

When each cable makes sense

RG58 can remain useful for short, moderate-frequency connections where cost, available connectors and a proven installation favor it. A lower-loss compact feeder is useful when a long run or higher operating frequency makes attenuation expensive in the link budget.

An antenna upgrade may deliver less benefit than a feeder upgrade if cable loss consumes the added gain. Compare the net antenna-system change rather than buying the highest-gain antenna first. For very long or high-frequency runs, a larger feeder or a different equipment location may be the better choice.

Read SigmaRF's RG58 Coaxial Cable Explained guide for the cable-family context and Understanding Coax Cable Datasheets for loss and velocity definitions. This comparison focuses on a compact feeder upgrade, not on every RG58 or LMR variant.

  • ✓Measure available conduit, gland and panel-entry space.
  • ✓Specify the selected cable part number, not only "RG58 equivalent".
  • ✓Match each connector's termination to the cable construction.
  • ✓Include installation bends, flex requirements and complete assembly loss limits.

Worked engineering example

For a 10 m run at 900 MHz, use the datasheet values above and assume matched ports. This calculation estimates bulk-cable loss only.

RG58/U: 13.7 dB / 30.48 m × 10 m = 4.49 dB
LMR-240: 24.8 dB / 100 m × 10 m = 2.48 dB
Cable-only difference = 2.01 dB
Output-power ratio = 10^(2.01/10) = approximately 1.59

The lower-loss run delivers about 1.59 times as much output power under these assumptions. It does not amplify the signal; it wastes less input power. Include connectors, adapters, mismatch and environmental conditions before setting a final link budget.

Mistakes to avoid

  • ✗Calling the cables the same diameter. 4.90 mm and 6.10 mm are not interchangeable gland or ferrule dimensions.
  • ✗Comparing dB/100 ft with dB/100 m without conversion.
  • ✗Publishing one attenuation curve as a guarantee for all RG58 products.
  • ✗Treating a solid-conductor feeder as a continuously flexing cable.
  • ✗Reusing RG58 termination tools and strip dimensions without checking the LMR-240 connector drawing.

Frequently Asked Questions

Is LMR-240 the same size as RG58?

No. Standard LMR-240 is approximately 6.10 mm in diameter, while the reference RG58/U product is 4.90 mm. Both are compact cables, but connector ferrules, seals and bend clearances differ.

How much lower is LMR-240 loss than RG58?

At 900 MHz in this comparison, the reference RG58/U cable is approximately 0.449 dB/m and standard LMR-240 is 0.248 dB/m. The difference depends on frequency and the exact RG58 product.

Can I reuse an RG58 connector on LMR-240?

Only if the connector manufacturer explicitly qualifies that termination for the selected cable. Match conductor, dielectric, shield and ferrule dimensions; the mating-interface name alone is not enough.

Is LMR-240 better for a 10 m antenna run?

It can reduce feeder loss substantially compared with conventional RG58. Check operating frequency, routing space, cable variant and complete assembly loss before choosing.

Does lower-loss coax increase transmitter power?

No. It delivers more of the existing transmitter power to the antenna by reducing attenuation. It does not provide gain or increase the transmitter's output.

Can standard LMR-240 be used for constant flexing?

Do not assume so. Standard cable construction and installation bend limits do not establish dynamic fatigue life. Use a flex-qualified cable and assembly for repeated motion.

Bottom Line

Treat this as a loss-and-routing comparison, not a drop-in replacement guide. The lower-loss feeder can be worthwhile, but the cable, connector termination and installation must change together.

Ask for loss at the real operating band, the exact cable variant and a tested finished assembly. A clear drawing and acceptance limit are more useful than a promise that a cable is "better than RG58."

SigmaRF VNA-sweeps every assembly for VSWR and insertion loss before shipment. Its testing capability spans 100 MHz to 40 GHz; each assembly is specified for its own operating band. Builds are supported by the Vadodara volume facility and Cleveland-area precision facility. Lead times can be as short as 2 days, depending on the build and component availability.