Published on 11/5/2026
A new coaxial assembly goes on the vector network analyzer and the screen fills with traces: S11 hugging the bottom, S21 near the top, and two more curves the intern has never opened. The report needs one line - "does this cable pass?" - and every answer lives in those four little numbers with the S in front.
S-parameters look abstract until you attach each one to a question you already ask: how much comes back, how much gets through, and how much leaks the wrong way. This guide maps S11, S21, S12 and S22 onto the quantities you actually specify, with the dB arithmetic to read them fluently.
Key idea: Sij is the wave coming out of port i divided by the wave sent into port j. S11 is reflection (return loss), S21 is transmission (insertion loss or gain), S12 is reverse isolation and S22 is output match. In dB, -20 dB means 1% of the power; -10 dB means 10%.
On This Page
At low frequency you probe a node and read a voltage. At RF the wire between the source and your probe is itself part of the circuit - it is a transmission line, and the signal takes real time to cross it, as covered in how an RF signal travels through a cable. Voltage and current stop being single numbers and become forward and reflected waves superimposed on the line.
S-parameters describe a network in exactly those terms: send a known wave into a port, terminate everything else in the reference impedance (almost always 50 Ω), and measure what waves come out. The result is a small set of complex ratios - magnitude and phase versus frequency - that completely characterizes the linear behavior of the device.
| Parameter | Wave ratio | Everyday name | What it tells you |
|---|---|---|---|
| S11 | Reflected out of port 1 / incident into port 1 | Return loss, input match | How much of your signal bounces back from the input |
| S21 | Out of port 2 / into port 1 | Insertion loss (or gain), transmission | How much gets through to the far end |
| S12 | Out of port 1 / into port 2 | Reverse isolation | How much leaks backward through the device |
| S22 | Reflected out of port 2 / incident into port 2 | Output match | How well the output port is matched |
For a passive cable assembly, S21 and S12 are essentially equal (the cable works the same both ways), S11 and S22 are the match at each end, and all four are plotted against frequency. The insertion loss vs return loss vs VSWR guide covers the same ground from the specification side.
S-parameters are voltage (wave) ratios, and the dB conversion is 20 log₁₀ of the magnitude. Power goes as the square, so -20 dB of voltage ratio is 1% of the power. A few anchor points make any trace readable at a glance:
| S11 magnitude | Power reflected | VSWR equivalent | Verdict for a cable |
|---|---|---|---|
| 0 dB | 100% | Infinite | Open or short - total reflection |
| -10 dB | 10% | ~1.9:1 | Poor for an assembly |
| -14 dB | 4% | ~1.5:1 | Marginal |
| -20 dB | 1% | ~1.2:1 | Good |
| -26 dB | 0.25% | ~1.1:1 | Very good |
| -32 dB | 0.06% | ~1.05:1 | Excellent |
The same table read with S21 gives transmission: -1 dB of S21 means 79% of the power arrives, -3 dB means half. Ripple in S21 versus frequency hints at connector discontinuities; a smooth downward slope is just normal cable loss rising with frequency.
Magnitude is only half of an S-parameter. The phase of S21 tells you the electrical length of the path - how much delay the signal picks up - and its slope versus frequency is group delay. Phase-matched systems, phased arrays and any multi-path design care as much about S21 phase matching between cables as about their loss. That is why the test report for a phase-critical assembly lists phase, not just loss and match.
Want the S-parameters on your next assembly?
Every SigmaRF assembly is swept on a VNA for VSWR and insertion loss before it ships, and the sweep data is available with the order.
Talk to an EngineerA vector network analyzer generates a swept source, injects it into port 1, and measures the reflected and transmitted waves with directional receivers - then repeats in reverse for S12 and S22. The catch is that the instrument measures at its own ports; the cables and adapters between the VNA and your device add their own errors. Calibration (SOLT: short, open, load, thru) moves the measurement reference plane to the ends of the test cables, so what remains on screen is only your device. The VNA testing guide walks through the full sweep workflow.
For a 50 Ω coaxial assembly in the DC to 6 GHz range, a healthy production sweep shows S11 and S22 below -15 dB across the band (better than -20 dB for quality builds), S21 within a few tenths of a dB of the theoretical cable loss, and no sharp dips or spikes - those mark connector faults, kinks or a crushed section. A single bad termination shows up as a periodic ripple in both S11 and S21, because the reflections bounce between the two ends.
The screen says S11 = -14 dB at 900 MHz. Good or bad?
1. Convert dB to linear: |S11| = 10^(-14/20) = 0.20
2. Power reflected = 0.20^2 = 0.04 = 4%
3. Reflection coefficient G = 0.20
4. VSWR = (1+G)/(1-G) = 1.2/0.8 = 1.5:1
Verdict: marginal. A good assembly reads -20 dB or better,
which is VSWR 1.2:1 and 1% power reflected.
Avoid
What does S11 tell you about a cable?
How much signal reflects from the input end. S11 of -20 dB means 1% of the power bounces back, equivalent to about 1.2:1 VSWR. Lower (more negative) is better.
What is the difference between S11 and S21?
S11 is the reflected wave at the input; S21 is the transmitted wave reaching the output. S11 says how well the device is matched, S21 says how much signal survives the trip.
Why is S21 negative for a cable?
A passive cable only loses signal, so the output wave is smaller than the input and the dB value is negative. -3 dB of S21 means half the power arrived. Amplifiers have positive S21 - that is their gain.
What is S12 used for?
Reverse transmission - how much signal travels from output back to input. For cables it equals S21; for amplifiers and isolators it is the isolation spec, and you want it as small as possible.
Do I need all four S-parameters?
For a cable assembly, S11 and S21 answer most questions, but S22 catches a bad termination at the far end and S12 confirms the cable behaves the same in both directions. A full 2-port file is the complete fingerprint.
How do S-parameters relate to VSWR?
VSWR is computed from the magnitude of S11: VSWR = (1 + |S11|) / (1 - |S11|). They are two ways of stating the same match, which the VSWR and impedance matching guide develops further.
S11, S21, S12 and S22 are just four questions asked with waves: what comes back, what gets through, what leaks backward, and how the far end is matched. Read them in dB, convert the anchor points to power and VSWR until it is reflex, and never trust a trace that was not calibrated to the reference plane. Once fluent, a four-parameter sweep tells you everything about a cable assembly in one glance.
Assemblies shipped with real sweep data
Standard and custom coaxial assemblies, each VNA-swept for VSWR and insertion loss before it leaves our line.
Ed is a Sourcing & Marketing Expert at SigmaRF, writes content related to Technology and Engineering topics