Published on 11/5/2026
A 100 W UHF repeater on a hilltop runs through 20 metres of coax to its antenna. After a year, the cable jacket near the transmitter feels warm, the VSWR alarm trips on hot afternoons and the PA keeps folding back. Nothing is wrong with the radio. The cable was picked from a catalogue line that said "suitable for RF power" without anyone checking what that meant at 450 MHz, in summer, at this VSWR.
High-power cable selection is one of the few RF decisions where a wrong choice physically destroys hardware. This guide walks through the two limits that matter, how real cables compare, and how to pick with margin instead of hope.
Key idea: A coax cable’s power rating is not one number. Average power heats the cable, peak power stresses the dielectric voltage, and both fall as frequency, temperature and VSWR rise. Select against both limits with margin, and remember the connector usually fails first.
On This Page
Below roughly 10 W almost any decent coax works. Between 10 W and 100 W construction quality starts to matter. Above 100 W - typical for repeaters, broadcast drivers, induction heating and RF test racks - the cable and its connectors become engineered components with real limits.
Two different quantities share the word "power". Average power is the continuous heating load: how many watts flow for minutes or hours. Peak power is the instantaneous crest: pulsed radar, AM modulation peaks, or a mismatched surge. A 100 W average transmitter can easily show 400 W peaks. Each stresses the cable differently, and a cable that handles one can still fail the other.
Thermal limit (average power). Conductor loss turns watts into heat in the center conductor, and the skin effect concentrates that current in a thin surface layer, so resistance rises with frequency. The heat has to travel outward through the dielectric. The ceiling is set by the dielectric’s temperature rating: solid polyethylene softens around 85 °C, foam PE is lower, PTFE survives roughly 250 °C. Bigger cables move heat better, which is why power handling grows with cable diameter.
Voltage limit (peak power). The peak voltage between center conductor and shield is set by power and impedance: Vₚₑₐₖ = √(2 × P × Z₀). 1 kW into 50 Ω is about 316 V peak, and a 2:1 mismatch nearly doubles that at voltage maxima. If the field strength anywhere exceeds what the dielectric and air gaps can hold, you get corona, carbon tracking and eventually a punctured cable. This limit shrinks with altitude because thin air breaks down more easily.
Numbers below are typical catalogue figures at sea level, 40 °C ambient, VSWR 1:1. Treat them as comparison points, not guarantees - every manufacturer publishes its own curves.
| Cable | Dielectric | 100 MHz | 400 MHz | 1 GHz | 2 GHz |
|---|---|---|---|---|---|
| RG-58 (5 mm) | Solid PE | 190 W | 90 W | 55 W | 35 W |
| RG-316 (2.5 mm) | PTFE | 110 W | 55 W | 35 W | 25 W |
| LMR-240 (6 mm) | Foam PE | 590 W | 280 W | 180 W | 120 W |
| LMR-400 (10 mm) | Foam PE | 1.4 kW | 680 W | 420 W | 290 W |
| RG-213 (10 mm) | Solid PE | 780 W | 370 W | 220 W | 150 W |
| LMR-600 (15 mm) | Foam PE | 2.4 kW | 1.1 kW | 700 W | 480 W |
| 1/2 in corrugated | Foam PE | 4.5 kW | 2.2 kW | 1.3 kW | 900 W |
Two things stand out. First, ratings fall roughly with the square root of frequency, so a cable that is comfortable at 100 MHz may be hopeless at 2 GHz. Second, foam dielectrics beat solid PE of the same size because lower loss means less heat in the first place. PTFE cables like RG-316 punch above their size on temperature rating, but their small conductors still limit average power.
Catalogue ratings assume a matched load in mild conditions. Real installations need three deratings:
Step 01
Apply the VSWR multiplier
At 2:1 VSWR the voltage at standing-wave peaks is 1.5x the matched value and local heating roughly doubles near current maxima. A conservative rule is to halve the allowable average power at 2:1 and to re-check peak voltage against the breakdown rating.
Step 02
Derate for ambient temperature
A cable rated at 40 °C loses headroom fast inside a sealed cabinet at 60 °C. As a working rule, cut average power 1 to 2 percent for every degree above the rated ambient, more for foam dielectrics.
Step 03
Derate for altitude
Above about 1,500 m, thin air lowers the corona threshold. Peak power ratings can fall 20 to 40 percent by 3,000 m. Outdoor hilltop and airborne links need this check even at modest power.
Not sure your cable can take the power?
Send us your frequency, average and peak power, run length and environment. We will size the assembly and sweep it before it ships.
Talk to an EngineerIn the field, connectors fail long before cable. Each interface has its own ceiling: SMA connectors are comfortable to a few hundred watts at UHF, N-type roughly twice that, and 7/16 DIN exists precisely because N-type runs out of headroom in kilowatt cellular and broadcast feeders. Inside the connector, the solder or crimp joint concentrates current in a small area, so it heats first.
Practical consequences: keep connector count low in high-power runs, avoid adapters entirely above a few hundred watts, and make sure the termination is swept on a VNA after assembly - a poor joint shows up as return loss before it shows up as smoke. Every SigmaRF high-power assembly is VNA-swept for VSWR and insertion loss before it leaves the line, which catches resistive joints while they are still on the bench. For the connector side of the rating, see the RF connector power ratings table.
Step 01
Fix the real power numbers
Write down average power, peak power and duty cycle at the antenna end of the run. Include modulation peaks and any future upgrade. Guessing low here is how cables die.
Step 02
Pick the smallest cable whose derated rating clears both limits
Apply VSWR, temperature and altitude deratings to the catalogue curve at your operating frequency. Keep at least 3 dB (2x) margin on average power and clear the peak voltage with margin too.
Step 03
Check the loss budget separately
A cable can survive the power and still waste it. Total the run loss in dB; every 3 dB is half your transmitter power turned into heat in the cable. If loss is unacceptable, go up a size - bigger cable solves both problems at once. The attenuation guide has per-metre figures.
Step 04
Match the connector to the power class
N-type for a few hundred watts upward, 7/16 DIN for kilowatt-class feeders, SMA only for low hundreds of watts and below. Confirm the connector’s CW rating at your frequency, not just its name.
Step 05
Specify the assembly, not just the cable
Termination method, weatherproofing and bend discipline decide whether the rating survives installation. For cable-family detail, our RG213/RG214 high-power guide covers two workhorse HF/VHF types.
20 m feeder, 100 W average, 200 W peaks, VSWR 1.5:1
Candidate: LMR-400. Rating at 450 MHz ~ 650 W average.
VSWR 1.5 derating (x0.75): 650 -> ~490 W. Margin 4.9x. OK.
Peak voltage: sqrt(2 x 200 W x 50 ohm) = 141 V, x1.5 (VSWR) = 212 V.
Cable breakdown > 1,000 V. OK.
Loss: 0.07 dB/m x 20 m = 1.4 dB = 28 W dissipated in cable.
28 W of heat over 20 m is fine thermally, but it is 28% of
transmitter power wasted. Upgrade to LMR-600:
0.042 dB/m x 20 m = 0.84 dB = 17.6 W lost, 1.1 kW rating.
Result: LMR-600 assembly, N-type both ends.
Avoid
Can I use RG-58 for a 100 W transmitter?
Only at low frequency and short runs. RG-58 handles roughly 90 W average at 400 MHz with no margin, and its loss (about 0.2 dB/m at 450 MHz) would burn a third of your power in a 20 m run. Use LMR-400 class or better.
Why does the power rating drop with frequency?
Skin effect shrinks the conductive area as frequency rises, so resistance and heating per metre increase. The same dielectric temperature ceiling is then reached at lower input power.
What is the difference between average and peak power handling?
Average power is limited by heat build-up and dielectric temperature. Peak power is limited by voltage breakdown of the dielectric and air gaps. A cable must clear both; pulsed systems usually hit the peak limit first.
How much does VSWR really reduce power handling?
As a working rule, halve the allowable average power at 2:1 VSWR and check peak voltage at 1.5x the matched value. Severe mismatch is the most common hidden cause of high-power cable failure.
Is PTFE always better than polyethylene for power?
PTFE tolerates far higher temperature (roughly 250 °C vs 85 °C), so PTFE cables survive abuse. But small PTFE cables like RG-316 still have small conductors that limit average power. Size and loss matter as much as dielectric.
Which connector should I use above 500 W?
N-type is the usual choice into the high hundreds of watts at UHF; 7/16 DIN is the standard for kilowatt-class feeders. SMA should stay in the low hundreds of watts and below.
High-power coax selection is a two-limit problem: average power against heat, peak power against voltage, both derated for frequency, VSWR, temperature and altitude. Pick the smallest cable that clears both limits with 2x margin, check that its loss does not waste the power you paid for, and treat the connector as the component most likely to fail. Specify the whole assembly, and have it swept before it ships.
Need a high-power assembly sized and tested?
Tell us your frequency, power and run length. Standard and custom coaxial assemblies, each one VNA-swept for VSWR and insertion loss before dispatch.
Ed is a Sourcing & Marketing Expert at SigmaRF, writes content related to Technology and Engineering topics