How to Crimp an SMA Connector onto RG174, RG316 or RG58 (Step by Step)

Published on 10/23/2026 • Updated on 10/23/2026

SigmaRF banner: how to crimp an SMA connector

A crimped SMA looks simple: strip, crimp, done. Then the assembly fails a pull test, or worse, it passes and fails in the field because the braid never made contact and the shield was a suggestion. Most crimp failures are baked in at the strip stage, long before the die closes.

This is the full bench procedure for crimping SMA plugs and jacks onto the three cables that make up most small-coax work: RG174, RG316 and RG58. Strip dimensions, die sizes, solder vs crimp pins, and the two checks that catch a bad crimp before it ships.

On This Page

Tools and parts you need

  • A ratchet crimp tool with the correct hex die set for the connector and cable pair. Pliers are not a crimp tool.
  • A coax strip tool or a sharp blade and a steady hand. A rotary strip tool pays for itself in repeatability within a day.
  • Flush cutters, a small pick for the braid, and heat-shrink for the strain relief.
  • The connector kit: body, center pin, crimp ferrule, and any heat-shrink or boot. Confirm the connector is built for your exact cable. An SMA for RG58 and an SMA for RG316 are different parts.
  • A multimeter for the continuity check and, ideally, a scale or fixture for the pull test.

If you are still picking the connector family, the SMA connector guide covers the variants, and the identification chart helps confirm what you are holding.

Strip dimensions by cable

Strip dimensions come from the connector maker, not from the cable. The values below are typical for common SMA crimp plugs; confirm against the drawing for your specific part, because a millimeter of error here becomes a failure mode later.

CableJacket stripBraid fold-backDielectric and center conductor exposedTypical ferrule hex die
RG174about 8 mmabout 3 mmabout 3 to 4 mm0.128 in (3.25 mm)
RG316about 8 mmabout 3 mmabout 3 to 4 mm0.128 in (3.25 mm)
RG58about 10 mmabout 4 mmabout 4 mm0.213 in (5.41 mm)

The numbers that matter most are the ones you cannot see after assembly: how far the dielectric sits inside the body and whether the center conductor fully enters the pin. Measure twice at the bench, not after the crimp.

Step by step: crimp the SMA

  1. Slide the heat-shrink and the crimp ferrule onto the cable first. Everyone forgets once; the fix is cutting the connector off.
  2. Strip the jacket to the dimension in the table. Do not nick the braid. Nicked braid strands become the short you chase next month.
  3. Flare the braid gently and fold it back over the jacket. Trim stray strands so none can wander toward the center conductor.
  4. Strip the dielectric and expose the center conductor to the pin dimension. The conductor should be straight, untinned and clean.
  5. Fit the center pin. For a solder pin, solder it and inspect for wicking and cold joints. For a crimp pin, crimp with the small die. The pin shoulder must sit flush against the dielectric.
  6. Push the body on until the pin seats at its final depth and the braid sits over the body tail. The dielectric must be visible in the inspection holes or flush at the reference face, per the drawing.
  7. Slide the ferrule over the braid-covered tail and crimp with the correct hex die, one full ratchet cycle. No second squeeze, no partial release.
  8. Slide the heat-shrink forward and shrink it as strain relief.

Hex die sizes

The die is chosen by the ferrule, which is chosen by the cable. Using the RG58 die on an RG316 ferrule crushes the cable; the reverse leaves the ferrule loose enough to pull off by hand. Common pairings: RG174 and RG316 ferrules typically crimp on a 0.128 inch hex, RG58 on 0.213 inch. Always confirm against the connector drawing, and always crimp on the hex size stamped for the ferrule, never by eye.

Solder pin vs crimp pin

Both are legitimate. A soldered pin gives a reliable joint when the operator tins correctly and avoids wicking solder up the conductor, which stiffens it and creates a fatigue point. A crimped pin is faster, needs no heat near the dielectric, and is the better choice in volume, but it demands the right small die and a calibrated tool. What is not legitimate: a pin that is neither soldered nor crimped, held by hope and heat-shrink.

Pull test and continuity check

Two checks catch nearly every bad crimp:

  1. Continuity and short check. Meter center-to-center for continuity, then center-to-shell for a short. A short here means a stray braid strand, and no amount of wishful thinking will fix it. Cut and redo.
  2. Pull test. A firm straight pull on the connector, or a measured pull per your quality standard, should move nothing. Any slip at the ferrule means the die size was wrong or the ratchet did not complete.

For assemblies that ship to customers, add a VSWR or insertion-loss sweep. A crimp can pass both bench checks and still show a impedance bump from a crushed dielectric, which is one reason factory assemblies are 100% tested before shipment.

Common failures and what they look like

  • Shorted braid. A single strand reaches the center pin. Found instantly with a meter. Cause: sloppy braid trim or nicked braid at the strip.
  • Crushed dielectric. The ferrule or body deformed the cable. The assembly works on the bench and shows a VSWR bump on a sweep. Cause: wrong die size or over-compression.
  • Pin backed out. The center pin was not fully seated or the conductor was too short. Intermittent contact that comes and goes with cable movement.
  • Ferrule slip. The connector slides on the cable under modest pull. Cause: wrong die, incomplete ratchet cycle, or braid not properly flared over the tail.

Crimping questions

Can I crimp SMA connectors with pliers in a pinch?

No. Pliers deform the ferrule unevenly and the joint will slip or fail the shield contact. A proper ratchet tool with the correct hex die is the only reliable method.

Is RG316 crimped the same way as RG174?

The procedure is identical and both typically use the same 0.128 inch ferrule die, but the connectors themselves are cable-specific. Use the part specified for your cable.

Solder pin or crimp pin: which is better?

Both work. Solder is forgiving in low volume with a skilled hand; crimp pins are faster and more repeatable in volume. Pick one method and control it, rather than mixing.

How do I know the crimp is good without a VNA?

Meter for continuity and center-to-shell shorts, then pull test. That catches the mechanical and wiring faults. What it cannot catch is a subtle impedance disturbance from a crushed dielectric, which is why shipped assemblies get a sweep.

Bottom Line

Good crimps are made at the strip stage: correct dimensions for the specific connector, clean braid, seated pin, right hex die, one full ratchet cycle. Then prove it with a meter and a pull test. When the volume or the stakes do not justify bench time, a factory-built and tested assembly costs less than the failures.

Skip the crimping entirely