Published on 11/6/2026
A 915 MHz industrial transmitter fails its emissions test. The carrier is clean, but its second harmonic at 1,830 MHz sits 35 dB above the limit. The fix is not a new power amplifier or a new layout. It is a low-pass filter between the amplifier and the antenna, chosen so the carrier passes with less than half a dB of loss while the harmonic is pushed down by 40 dB or more.
That choice, which response shape to use, is the first decision in every filter design. Low-pass, high-pass, band-pass and band-stop filters all do the same job in different directions: they pass the energy you want and reject the energy you do not. This guide explains what each response does, how the classic approximations (Butterworth, Chebyshev, elliptic, Bessel) trade ripple against steepness, and how to pick a response from real system numbers.
Key idea: The filter response is the shape of transmission versus frequency. Pick the response family first (low-pass, high-pass, band-pass, band-stop), then the approximation (Butterworth, Chebyshev, elliptic, Bessel), then the order that meets your rejection target. Technology choice, lumped, ceramic, cavity or acoustic, comes last.
On This Page
On a network analyzer, every filter shows the same plot: S21 in dB on the vertical axis, frequency on the horizontal. The response name just describes which part of the frequency axis is allowed through.
| Response | Passes | Rejects | Typical jobs |
|---|---|---|---|
| Low-pass | DC up to the cutoff frequency fc | Everything above fc | Harmonic suppression after power amplifiers, anti-alias filtering |
| High-pass | Everything above fc | DC and low frequencies below fc | Removing DC and low-frequency noise, blocking AM/FM broadcast from a UHF receiver |
| Band-pass | One band between f1 and f2 | Everything below f1 and above f2 | Receiver channel selection, transmitter band cleanup |
| Band-stop (notch) | Everything except one band | One band between f1 and f2 | Removing a single known interferer, protecting a measurement from a strong local signal |
The boundary frequency is called the cutoff (fc) for low-pass and high-pass filters, and the center frequency (f0) with a bandwidth (BW) for band-pass and band-stop types. Edges are normally quoted at the 3 dB point, where transmission has fallen to about 71% of its passband voltage.
A low-pass filter passes everything from DC up to its cutoff and rolls off above it. Its everyday RF job is harmonic control. A power amplifier running at 900 MHz also produces energy at 1,800 MHz, 2,700 MHz and beyond. A low-pass with a cutoff around 1 GHz passes the wanted carrier and attenuates every harmonic.
Two practical notes. First, rejection keeps improving as frequency rises, so a low-pass is the natural choice when everything to be removed sits above the band you want. Second, the filter still has to handle the power: after a 50 W amplifier, the filter sees 50 W, so lumped-element or ceramic parts must be rated for the current and voltage. The cable and connectors after the filter matter too, and our high-power RF coaxial cable selection guide covers that side of the chain.
A high-pass filter is the mirror image: it blocks DC and low frequencies and passes everything above cutoff. Use it when the threat lives below your signal. A 2.4 GHz telemetry receiver, for example, sits in the same spectrum neighborhood as powerful FM broadcast transmitters near 100 MHz and switching-power-supply noise in the kilohertz to low-megahertz region. A high-pass with a cutoff near 2 GHz sweeps all of that away before the first amplifier.
High-pass filters also block DC, which makes them handy in front of instruments that must not see a DC offset. The trade-off: a high-pass does nothing about interferers above your band, so it is often paired with a low-pass or band-pass elsewhere in the chain.
A band-pass filter passes one contiguous band and rejects both sides. This is the workhorse of receivers. A GNSS receiver listening at 1,575.42 MHz wants only a few MHz around that line and rejection of cellular signals hundreds of MHz away. A band-pass does exactly that, in one part.
The key specification is fractional bandwidth, the passband width divided by the center frequency. Narrow fractional bandwidths (under about 5%) demand high-Q resonators and get harder and lossier as they shrink; wide ones are easier. When you compare technologies for a narrow band-pass, our article on how microwave filters work walks through LC, microstrip, cavity, ceramic and acoustic implementations.
A band-stop, or notch, filter passes nearly everything and rejects one band. It exists for one situation: a single strong interferer you can name. An SDR receiver desensitized by a local 2.4 GHz transmitter, a spectrum analyzer that needs a strong FM station removed to see a weak signal near it, or a two-radio installation where one transmitter blinds the other receiver. A notch tuned to the interferer restores the rest of the spectrum without redesigning the whole front end.
Notch depth and notch bandwidth trade against each other. Deeper notches are narrower, so the interferer frequency must be known and stable. If the threat drifts, a band-stop is the wrong tool; re-plan with a band-pass instead.
Need a filter and cable chain that actually meets spec?
Send us your passband, stopband and rejection numbers. We will tell you what is practical and supply the assemblies to match.
Talk to an EngineerWithin each response family, the approximation polynomial decides how the filter moves from passband to stopband. Four classic shapes cover most designs.
| Approximation | Passband ripple | Steepness | Group delay | Use when |
|---|---|---|---|---|
| Butterworth | None (maximally flat) | Moderate: about 6 dB per octave per pole | Good, smooth | You want a clean, predictable shape with no surprises |
| Chebyshev | Controlled ripple (e.g. 0.1 dB) | Steeper than Butterworth for the same order | Ripples at band edges | You need more rejection per pole and can accept small ripple |
| Elliptic (Cauer) | Ripple in pass and stop bands | Steepest possible for a given order | Poorest near edges | Rejection must start immediately outside the passband |
| Bessel | Very flat | Gentlest slope | Flattest (constant delay) | Pulse and data waveforms where shape matters more than rejection |
Order counts poles, roughly the number of resonant elements. A Butterworth rolls off at about 6 dB per octave per pole beyond cutoff, so doubling the distance from cutoff adds 6 dB of rejection per pole. Chebyshev and elliptic reach a given rejection with fewer poles by accepting ripple. Fewer poles mean fewer resonators, lower loss and lower cost, which is why the ripple trade is usually worth taking.
Back to the failing transmitter. The carrier is 915 MHz, the second harmonic at 1,830 MHz needs 40 dB of extra suppression, and the passband must keep insertion loss under 0.5 dB.
LOW-PASS SIZING FOR A 915 MHz TRANSMITTER
Wanted signal: 915 MHz (pass with < 0.5 dB loss)
Unwanted harmonic: 1,830 MHz (reject by >= 40 dB)
Filter cutoff: fc = 1,000 MHz
Frequency ratio: f / fc = 1,830 / 1,000 = 1.83
Butterworth rejection = 10 x log10(1 + (f/fc)^(2n))
n = 7 poles: 10 x log10(1 + 1.83^14) = 36.7 dB -> short
n = 8 poles: 10 x log10(1 + 1.83^16) = 42.0 dB -> OK
Chebyshev 0.1 dB ripple reaches about 41 dB at n = 6
Result: 8-pole Butterworth, or 6-pole Chebyshev with
0.1 dB passband ripple and lower insertion loss.
The Chebyshev option wins on size and loss because it buys rejection with ripple instead of poles. If the transmitter also feeds a sensitive multi-band antenna, confirm the filter S11 across the passband, since a reactive stopband reflects harmonic energy back into the amplifier, and check the reflection with the S-parameter basics in our S11, S21, S12 and S22 guide.
Do this
Avoid
What is the difference between low-pass and band-pass filters?
A low-pass passes everything from DC to its cutoff and rejects all higher frequencies. A band-pass passes only one band and rejects both lower and higher frequencies. Use low-pass when all the unwanted energy is above your signal; use band-pass when you need one channel isolated from both sides.
How do I choose the cutoff frequency of a low-pass filter?
Place it above the highest frequency you must pass, with 5 to 10% margin for tolerance and temperature, and as far below the first frequency you must reject as practical. A larger gap between pass and reject means fewer poles for the same rejection.
What is a notch filter used for in RF?
A notch (band-stop) filter removes one narrow, known band while passing the rest. Typical uses are removing a strong local transmitter, an FM broadcast station or a clock harmonic that desensitizes a receiver or measurement.
Is Chebyshev better than Butterworth?
It depends on what you optimize. Chebyshev gives steeper rejection for the same number of poles by accepting controlled passband ripple. Butterworth has no ripple and smoother delay. If you can tolerate 0.1 to 0.5 dB of ripple, Chebyshev usually wins on size and loss.
What order filter do I need for 40 dB of rejection?
It depends on how far the stopband is from the passband. A Butterworth rolls off about 6 dB per octave per pole. If the interferer is one octave from cutoff, 40 dB needs about 7 poles. Chebyshev and elliptic responses reach the same rejection with fewer poles.
Can I cascade two filters for more rejection?
Yes, and their rejections add in dB. Watch for passband interaction: two filters in series also add insertion loss and can create mismatch ripple if their S11s interact. Leave an attenuator or some cable length between them if the combined passband ripple matters.
Filter responses are four answers to one question: which frequencies get through. Low-pass removes everything above, high-pass everything below, band-pass keeps one slice and band-stop removes one slice. Pick the family from where the interference lives, pick the approximation from how much ripple you can accept, and count poles from the rejection target. Get those three decisions right and the technology choice becomes a purchasing exercise.
Need cable assemblies that respect your filter budget?
Every SigmaRF assembly is swept on a VNA for VSWR and insertion loss before it ships, so the cable never eats the margin your filter just created.
Alankar is a Technical Content Writer at SigmaRF, writes on various topics from Technology, Compliance and Business process